Summary for Test 2023-02-09-18-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 993442 DEA: 07323304 EFIS: 0716000063 |
---|---|
DIST-CO-RTE-PM | 07-LA-60-R28.0/R30.4 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | INSTALL DPP INFILTRATION AND CONSTRUCT MAINTENANCE VEHICLE PULLOUT. |
Location Description | LOS ANGLES COUNTY IN POMONA AT VARIOUS LOCATIONS FROM PHILLIPS RANCH ROAD OVERCROSSING TO 0.1 MILE EAST OF RESERVOIR STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 12/16/2021) |
Sample Information
Sample Taken Date | 02/09/2023 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/09/2023 |
Sample type | Acceptance | A brief description of the sample | Aggregate Base |
The quantity of what the sample constitutes | 1152 SF | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Michelangelo | Last name of sampler or witnessed by | Sese |
Title of sampler | TET | Telephone number of sampler | 310-345-6204 |
Laboratory sample identification | 23-0150 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Aggregate Base |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Various locations | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-02-09-18
DIME Test ID: 2023-02-09-18-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-02-10
Test Results
Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Michelangelo Sese
Date of test: 02/09/2023
Gage No.: 60203
Test No.: no data
Nuclear By: Michelangelo Sese
Non-Bias Plan No.: 3
Depth: 5
Material No.: no data
Material Type: Aggregate Base
Impact By: Michelangelo Sese
Standard Count Density: 2314 g/cc
Count or Density 1: 2.04 g/cc
Count or Density 2: 1.99 g/cc
Count or Density 3: 1.97 g/cc
Standard Count Moisture: 639 g/cc
Moisture Count 1: 0.18 g/cc
Moisture Count 2: 0.16 g/cc
Moisture Count 3: 0.16 g/cc
Sum of Count or Density: 6.00 g/cc
Average of Count or Density: 2.00 g/cc
Sum of Moisture Count: 0.50 g/cc
Average of Moisture Count: 0.17 g/cc
Calculated Percent Relative Compaction: 93.9 %
Reported Percent Relative Compaction: 94 %
General comments (publicly viewable) (Max 1000 characters): EB Rte. 60 MVP
Location 1 @ SB Phillips Ranch Rd On-Ramp
Sta. 75+52 to Sta. 76+48
Test was verified on 2/10/2023 ✔