Summary for Test 2023-01-26-35-4

Test performed: ASTM C128-12

Project Information

Project IdentifiersProject ID: 994358
DEA: 033J3304
EFIS: 0322000251
DIST-CO-RTE-PM03-SAC/SAC-12-0/0.5
Award DateNot set
Closeout DateNot set
Work DescriptionReplace backup drive system, replace lift span deck, install hydraulic barrier system and new generator, replace electrical control system, install new traffic gates and elevators, traffic control,
Location DescriptionNot set
QA Service Level1 (Verified on 10/25/2022)

Sample Information

Sample Taken Date01/26/2023 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/27/2023
Sample typePer Request A brief description of the sample lightweight Sand
The quantity of what the sample constitutes1-5 gallon bucket From where was the sample collectedSource
First name of sampler or witnessed byRusty Last name of sampler or witnessed byD'Anna
Title of samplerSR Telephone number of sampler
Laboratory sample identification23-LWF-0007 Linked DIME Sample ID
The fabricator/manufacturer/facility namena Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)0000
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedVolumetric Truck
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-01-26-35
DIME Test ID: 2023-01-26-35-4
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: ASTM C128-12: Standard Test Method for Relative Density (Specific Gravity) and Absorption of Fine Aggregate
Test Release Date: 2023-02-03

Test Results


What procedure was used?: Gravimetric Procedure
Basis for testing: Saturated Surface Dry
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 02/03/2023
Mass of saturated surface dry sample: 250.3 grams
Mass of pycnometer, sample and water: 778.5 grams
Mass of pycnometer and water: 662.2 grams
Mass of oven dried sample: 220.2 grams
Specific Gravity: 1.87
Density: 1860 kg/m^3
Absorption: 13.67 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/3/2023