Summary for Test 2023-01-11-5-1
Test performed: ASTM A970-18Project Information
Project Identifiers | Project ID: 208973 DEA: 120H1004 EFIS: 1200000180 COOP: 120670 |
---|---|
DIST-CO-RTE-PM | 12-ORA-405,73,405,605-9.3/24.3 |
Award Date | 11/07/2016 |
Closeout Date | Not set |
Work Description | (Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP. |
Location Description | Orange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2 |
QA Service Level | 1 (Verified on 09/10/2015) |
Sample Information
Sample Taken Date | 01/11/2023 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/17/2023 |
Sample type | Quality Assurance | A brief description of the sample | #11 HRC 120 T-Heads |
The quantity of what the sample constitutes | 112 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Hall |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 949-350-3970 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | HRC Fountain Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L134-012-23 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 6035687 | Head Manufacturer Lot Number(s) | 1 |
Rebar Size | #11 | Headed Bar Model Name | HRC 120 |
Size of Head | Full Size - 9x | Head Connection Type | Friction Weld |
Head Shape | Square | Rebar Manufacturer | CMC Steel Arizona |
Head Manufacturer | HRC Fountain Valley | Head Fabricator | HRC Fountain Valley |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | 9FW-17-04 |
Test Details
DIME Sample ID: 2023-01-11-5
DIME Test ID: 2023-01-11-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2023-01-20
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 01/18/2023
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 1.56 | 152256 | 97600 | ok necking | spaine |
General comments (publicly viewable) (Max 1000 characters): ok necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 1/20/2023 ✔