Summary for Test 2022-12-02-10-3

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 993607
DEA: 07322604
EFIS: 0716000057
DIST-CO-RTE-PM07-LA-210-R41.3/R44.6
Award DateNot set
Closeout DateNot set
Work DescriptionCONSTRUCT POLLUTION INFILTRATION AREAS AND AUSTIN VAULT SAND FILTER.
Location DescriptionLOS ANGELES COUNTY IN GLENDORA AT VARIOUS LOCATIONS FROM 0.2 MILE EAST OF BARRANCA AVENUE OVERCROSSING TO 0.1 MILE WEST OF AMELIA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date12/02/2022 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/05/2022
Sample typeAcceptance A brief description of the sample4X8 PCC cylinders
The quantity of what the sample constitutes130 CY From where was the sample collectedJob Site
First name of sampler or witnessed byRamon Last name of sampler or witnessed byMantuano
Title of samplerAssistant Structure Representative Telephone number of sampler
Laboratory sample identification22-0370 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertsons Ready Mix Concrete Transportation Laboratory (TL) Number7319243
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberSC675B38
The truck number from where the sample was collected4 The batch plant ticket number from where the sample was collected7319243
Concrete batch plantRobertsons Ready Mix Concrete The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-12-02-10
DIME Test ID: 2022-12-02-10-3
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-01-13

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 01/13/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.02 in
Maximum load on cylinder 1: 72314 lb
Maximum load on cylinder 2: 71810 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 42 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.69 in^2
Compressive strength of cylinder 1: 5698.5 psi
Compressive strength of cylinder 2: 5658.8 psi
Compressive strength (to nearest 10 psi): 5680 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/13/2023