Summary for Test 2022-12-30-9-2
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 214336 DEA: 07302404 EFIS: 0713000488 |
---|---|
DIST-CO-RTE-PM | 07-VEN-101-37/40 |
Award Date | 11/17/2020 |
Closeout Date | 09/24/2024 |
Work Description | PADRE JUAN REHAB |
Location Description | VEN 101 |
QA Service Level | 1 (Verified on 02/26/2021) |
Sample Information
Sample Taken Date | 12/30/2022 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/09/2023 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA AGGREGATE |
The quantity of what the sample constitutes | 100 Tons | From where was the sample collected | Source |
First name of sampler or witnessed by | Avo | Last name of sampler or witnessed by | Karajian |
Title of sampler | TET | Telephone number of sampler | 2137986076 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Granite Construction - Santa Paula | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0046 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Coldfeed Chute | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | 13762 | Lot number | 1 |
Sublot number | 2 | Aggregate Mix Number |
Test Details
DIME Sample ID: 2022-12-30-9
DIME Test ID: 2022-12-30-9-2
Testing Lab: CT D07 - Plant Services
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2023-01-30
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Avo Karajian
Date of test: 01/09/2023
Clay Level (Test 1): 5
Sand Level (Test 1): 4
Clay Level (Test 2): 4.9
Sand Level (Test 2): 3.9
Clay Level (Test 3): 5
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 80
Sand Equivalent (Test 2): 80
Sand Equivalent (Test 3): 76
Sand Equivalent: 79
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/30/2023 ✔