Summary for Test 2022-12-20-37-4

Test performed: ASTM D2240-15r21

Project Information

Project IdentifiersProject ID: 209698
DEA: 072332E4
EFIS: 0700000391
COOP: 0705187
DIST-CO-RTE-PM07-LA-I-5-45.4/54
Award Date07/01/2021
Closeout DateNot set
Work DescriptionAddition of 14 miles of HOV lanes in both directions would extend existing carpool lanes on the I- 5 in San Fernando Valley to Santa Clarita Valley
Location DescriptionThe I-5 North Capacity Enhancements Project focuses on improvements to the I-5 freeway from cities of Santa Clarita and Castaic, beginning at the SR-14 interchange to Parker Rd.
QA Service Level2 (Verified on 02/03/2021)

Sample Information

Sample Taken Date12/20/2022 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/27/2022
Sample typeQuality Assurance A brief description of the sampleBearing Pad
The quantity of what the sample constitutes5 From where was the sample collectedFabricator
First name of sampler or witnessed byBrad Last name of sampler or witnessed byStreeter
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameScougal Rubber Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)22178-1
Material/Compound/Elastomer IDNA Samples Representing243
Description (size)2x10x14 Comments
Description (Number of Shims)4 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)Scougal Rubber
Batch NumberNA

Test Details

DIME Sample ID: 2022-12-20-37
DIME Test ID: 2022-12-20-37-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Test Release Date: 2023-01-12

Test Results


Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 01/09/2023
Temperature: 72 f
Humidity: 50 %
Reading #1: 53
Reading #2: 55
Reading #3: 52
Reading #4: 57
Reading #5: 58
Mean: 55
General comments (publicly viewable) (Max 1000 characters): Hardness

Test was verified on 1/12/2023