Summary for Test 2022-12-21-41-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993545
DEA: 07328504
EFIS: 0716000178
DIST-CO-RTE-PM07-LA-210-R44.7/R52.1
Award DateNot set
Closeout DateNot set
Work DescriptionINSTALL DPP INFILTRATION AREA & CONSTRUCT MAINTENANCE VEHICLE PULLOUT
Location DescriptionLOS ANGELES COUNTY FROM 0.4 MILE EAST OF SOUTH LONE HILL AVENUE UNDERCROSSING TO COUNTY LINE
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date12/21/2022 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/22/2022
Sample typeDepartment Acceptance A brief description of the sample3/4" RHMA-G 226108A IRW LTR
The quantity of what the sample constitutes40 tons From where was the sample collectedManufacturer
First name of sampler or witnessed byVictor Last name of sampler or witnessed byPham
Title of samplerTET Telephone number of sampler
Laboratory sample identification22-0382 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials Irwindale Transportation Laboratory (TL) Number1221A2
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number226108A IRW LTR

Test Details

DIME Sample ID: 2022-12-21-41
DIME Test ID: 2022-12-21-41-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-01-03

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 12/27/2022
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2007.7 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1847.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.32 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 7.68 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/3/2023