Summary for Test 2022-12-20-18-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 994092 DEA: 07339204 EFIS: 0717000119 |
---|---|
DIST-CO-RTE-PM | 07-VEN-118-0.7/11.0 |
Award Date | 08/29/2022 |
Closeout Date | 12/01/2023 |
Work Description | REPLACE MINOR CONCRETE CURB RAMPS & MODIFY SIGNAL & LIGHTING SYSTEMS. |
Location Description | VENTURA COUNTY IN AND NEAR OXNARD FROM DARLING ROAD TO ROUTE 34/118 SEPARATION |
QA Service Level | 1 (Verified on 09/20/2022) |
Sample Information
Sample Taken Date | 12/20/2022 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/20/2022 |
Sample type | Department Acceptance | A brief description of the sample | Subgrade |
The quantity of what the sample constitutes | 8 yd2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Rosauro | Last name of sampler or witnessed by | Nogoy |
Title of sampler | TEC | Telephone number of sampler | 2137939321 |
Laboratory sample identification | 22-3203 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Toro | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Subgrade |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | From various locations at subgrade. | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2022-12-20-18
DIME Test ID: 2022-12-20-18-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-12-27
Test Results
Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Rosauro Nogoy
Date of test: 12/20/2022
Gage No.: 60202
Test No.: no data
Nuclear By: Rosauro Nogoy
Non-Bias Plan No.: 2
Depth: 3
Material No.: On site
Material Type: Subgrade
Impact By: Rosauro Nogoy
Standard Count Density: 2349 g/cc
Count or Density 1: 2.04 g/cc
Count or Density 2: 1.94 g/cc
Count or Density 3: 2.03 g/cc
Standard Count Moisture: 628 g/cc
Moisture Count 1: 0.08 g/cc
Moisture Count 2: 0.07 g/cc
Moisture Count 3: 0.06 g/cc
Sum of Count or Density: 6.01 g/cc
Average of Count or Density: 2.00 g/cc
Sum of Moisture Count: 0.21 g/cc
Average of Moisture Count: 0.07 g/cc
Calculated Percent Relative Compaction: 93.2 %
Reported Percent Relative Compaction: 93 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/27/2022 ✔