Summary for Test 2022-11-01-128-1
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 214336 DEA: 07302404 EFIS: 0713000488 |
---|---|
DIST-CO-RTE-PM | 07-VEN-101-37/40 |
Award Date | 11/17/2020 |
Closeout Date | 09/24/2024 |
Work Description | PADRE JUAN REHAB |
Location Description | VEN 101 |
QA Service Level | 1 (Verified on 02/26/2021) |
Sample Information
Sample Taken Date | 11/01/2022 | Sample Unique Key | 128 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/02/2022 |
Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinders JPCP |
The quantity of what the sample constitutes | 10 Cubic Yards | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Harrison | Last name of sampler or witnessed by | Kain |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 22-2969 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | n/a | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | G3-21-PCC-250HPR |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 9512 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Wheelbarrow | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-11-01-128
DIME Test ID: 2022-11-01-128-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-12-14
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Nathan Ogbasellasie
Date of test: 12/13/2022
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 5.96 in
Average diameter of cylinder 2: 5.97 in
Average diameter of cylinder 3: 5.97 in
Maximum load on cylinder 1: 160467 lb
Maximum load on cylinder 2: 163931 lb
Maximum load on cylinder 3: 165055 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 42 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 27.9 in^2
Cross sectional area of cylinder 2: 27.99 in^2
Cross sectional area of cylinder 3: 27.99 in^2
Compressive strength (to nearest 10 psi): 5840 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/14/2022 ✔