Summary for Test 2022-11-16-28-2
Test performed: ASTM D36-14ε1Project Information
Project Identifiers | Project ID: 214321 DEA: 012982U4 EFIS: 0118000125 |
---|---|
DIST-CO-RTE-PM | 01-LAK-29,175-28.5/31.6,8.2/8.5 |
Award Date | 11/07/2019 |
Closeout Date | Not set |
Work Description | CONSTRUCT 4 LANE EXPRESSWAY WITH EARTHWORK AND PAVING. |
Location Description | LAKE COUNTY NEAR KELSEYVILLE ON ROUTE 29 FROM 0.6 MILE TO 3.7 MILES NORTH OF ROUTE 281 AND ON ROUTE 175 FROM SOUTH JUNCTION ROUTE 29 TO 0.3 MILE EAST OF SOUTH JUNCTION ROUTE 29 |
QA Service Level | 1 (Verified on 08/19/2019) |
Sample Information
Sample Taken Date | 11/16/2022 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/28/2022 |
Sample type | Department Acceptance | A brief description of the sample | Asphalt Rubber Binder |
The quantity of what the sample constitutes | 1 OF 4 CANS | From where was the sample collected | Source |
First name of sampler or witnessed by | Loren | Last name of sampler or witnessed by | L |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero - Benicia, CA | Transportation Laboratory (TL) Number | 026619 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2022-11-16-28
DIME Test ID: 2022-11-16-28-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2022-12-01
Test Results
ASTM Thermometer used?: C
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 11/30/2022
Softening Point Sample 1: 73 C
Softening Point Sample 2: 74 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/1/2022 ✔