Summary for Test 2022-11-16-24-2
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 993318 DEA: 11423704 EFIS: 1116000059 |
---|---|
DIST-CO-RTE-PM | 11-SD-8-R31.8/R41.7 |
Award Date | 04/01/2022 |
Closeout Date | Not set |
Work Description | PLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM. |
Location Description | SAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE |
QA Service Level | 1 (Verified on 10/27/2021) |
Sample Information
Sample Taken Date | 11/16/2022 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/17/2022 |
Sample type | Quality Control | A brief description of the sample | 1x4 concrete aggregates |
The quantity of what the sample constitutes | 1 per batch | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Lee | Last name of sampler or witnessed by | Hernandez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | G3 | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-37-0035 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | belt cut | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2022-11-16-24
DIME Test ID: 2022-11-16-24-2
Testing Lab: Sequoia Consultants
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-11-23
Test Results
Number of tests: 2
Input Type: Calculated
Tester's full name: Larry Fukushima
Date of test: 11/19/2022
Temperature correction: 0
Temperature of solution: 77
Clay reading (test 1): 5.1
Sand reading (test 1): 4.2
Clay reading (test 2): 5.4
Sand reading (test 2): 4
Sand equivalent (test 1): 83
Sand equivalent (test 2): 75
Sand equivalent before temperature correction: 79
Sand equivalent after temperature correction: 79
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/23/2022 ✔