Summary for Test 2021-08-26-68-1
Test performed: AASHTO T315-22Project Information
Project Identifiers | Project ID: 214618 DEA: 033F99U4 EFIS: 0319000311 |
---|---|
DIST-CO-RTE-PM | 03-SUT-99-39.2/41.4 |
Award Date | 05/15/2020 |
Closeout Date | 12/13/2023 |
Work Description | WIDEN RDWY, HMA, CRCP, WATER LINE, SIGNALS, & LIGHTING SYSTEM. |
Location Description | SUTTER COUNTY IN AND NEAR LIVE OAK FROM 0.1 MILE SOUTH OF COLEMAN AVENUE TO NEVADA STREET (NORTH INTERSECTION) |
QA Service Level | 1 (Verified on 03/24/2020) |
Sample Information
Sample Taken Date | 08/26/2021 | Sample Unique Key | 68 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/09/2022 |
Sample type | Acceptance | A brief description of the sample | PG58-22 |
The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Source |
First name of sampler or witnessed by | _ | Last name of sampler or witnessed by | _ |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | DeSilva Gates - Marysville | Transportation Laboratory (TL) Number | - |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | No | Lot number | 2 |
Sublot number | 15 | Tank number | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2021-08-26-68
DIME Test ID: 2021-08-26-68-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-11-28
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 11/21/2022
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.279 kPa
Phase Angle (δ) (for the 10 cycles): 83.1 degree
Complex Modulus (G*) (for the 10 measurements): 2.326 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 2.34 kPa
General comments (publicly viewable) (Max 1000 characters): original. For information only
Test was verified on 11/28/2022 ✔