Summary for Test 2016-09-20-3-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 209060
DEA: 041A2904
EFIS: 0400000482
DIST-CO-RTE-PM04-SON-12-9.6
Award Date03/11/2014
Closeout Date01/10/2019
Work DescriptionREPLACE BRIDGE AND WIDEN APPROACHES.
Location DescriptionSONOMA COUNTY NEAR THE CITY OF SEBASTOPOL AT LAGUNA DE SANTA ROSA BRIDGE
QA Service Level1 (Verified on 01/23/2014)

Sample Information

Sample Taken Date09/20/2016 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/22/2016
Sample typeQuality Control A brief description of the sampleconcrete
The quantity of what the sample constitutescylinders From where was the sample collectedJob Site
First name of sampler or witnessed byj Last name of sampler or witnessed bychi
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) Number256235
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberb7181sra
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedunk
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedunk Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-09-20-3
DIME Test ID: 2016-09-20-3-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-10-18

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 10/18/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 145675 lb
Maximum load on cylinder 2: 152087 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength of cylinder 1: 5186.0 psi
Compressive strength of cylinder 2: 5397.0 psi
Compressive strength (to nearest 10 psi): 5290 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 10/18/2016