Summary for Test 2022-10-19-69-1
Test performed: AASHTO T315-22Project Information
Project Identifiers | Project ID: 993208 DEA: 034F38U4 EFIS: 0321000092 |
---|---|
DIST-CO-RTE-PM | 03-YUB-70-16.2/25.8 |
Award Date | 11/04/2021 |
Closeout Date | Not set |
Work Description | WIDEN SHOULDERS AND IMPROVE CLEAR RECOVERY ZONE. |
Location Description | YUBA COUNTY NEAR MARYSVILLE FROM 0.2 MILE NORTH OF LAURELLEN ROAD TO SOUTH HONCUT CREEK BRIDGE |
QA Service Level | 1 (Verified on 09/10/2021) |
Sample Information
Sample Taken Date | 10/19/2022 | Sample Unique Key | 69 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/04/2022 |
Sample type | Acceptance | A brief description of the sample | PG58-22 |
The quantity of what the sample constitutes | 1 of 1 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jeremy | Last name of sampler or witnessed by | _ |
Title of sampler | Plant QC | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Desilva Gates-Marysville | Transportation Laboratory (TL) Number | 802972 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | No | Lot number | 6 |
Sublot number | 14 | Tank number | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | Yes |
Multigrade Type | PG 58-22 / PG 58-16 | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2022-10-19-69
DIME Test ID: 2022-10-19-69-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-11-15
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 11/14/2022
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.206 kPa
Phase Angle (δ) (for the 10 cycles): 84.7 degree
Complex Modulus (G*) (for the 10 measurements): 1.716 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 1.72 kPa
General comments (publicly viewable) (Max 1000 characters): OG
Test was verified on 11/15/2022 ✔