Summary for Test 2022-10-27-41-1
Test performed: AASHTO T316-17Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/27/2022 | Sample Unique Key | 41 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/27/2022 |
Sample type | Quality Control | A brief description of the sample | Asphalt Binder Sample |
The quantity of what the sample constitutes | 2 qts | From where was the sample collected | Source |
First name of sampler or witnessed by | Tom | Last name of sampler or witnessed by | Reneau |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Western Emulsions - White City OR | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Western Emulsion - White City Emulsion Plant - White City OR | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2022-10-27-41
DIME Test ID: 2022-10-27-41-1
Testing Lab: Western Emulsions, Incorporated - White City Emulsion
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2022-11-10
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Elena Hubert
Date of test: 10/27/2022
Time of test: 9:33 HH:MM
Test Temperature: 135 C
Speed: 20 rpm
Spindle size: 21 in
Torque: 11 %
Viscosity reading #1 (A) : 0.284 Pa-s
Viscosity reading #2 (B) : 0.281 Pa-s
Viscosity reading #3 (C): 0.279 Pa-s
Average viscosity: 0.281 Pa-s
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/10/2022 ✔