Summary for Test 2022-11-01-7-1

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 214627
DEA: 05344904
EFIS: 0500000505
DIST-CO-RTE-PM05-SBT-156-3/R8.2
Award Date05/19/2022
Closeout DateNot set
Work DescriptionSAN BENITO ROUTE 156 IMPROVEMENT PROJECT SAN BENITO RTE 156 IMPROVEMENT PROJECT; INCLUDES NEW BRIDGE AND WIDENING OF EXISTING BRIDGE.
Location DescriptionSAN BENITO COUNTY IN AND NEAR SAN JUAN BAUTISTA FROM THE ALAMEDA TO 0.2 MILE EAST OF FOURTH STREET/BUSINESS ROUTE 156
QA Service Level1 (Verified on 01/14/2020)

Sample Information

Sample Taken Date11/01/2022 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/07/2022
Sample typeQuality Assurance A brief description of the sampleHRC 150 T-Heads
The quantity of what the sample constitutes142 From where was the sample collectedManufacturer
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Telephone number of sampler213 435 4055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Fountain Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-197-22 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)6034674 Head Manufacturer Lot Number(s)100011635523
Rebar Size#6 Headed Bar Model NameHRC 150
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeCircular Rebar ManufacturerCMC Oklahoma
Head ManufacturerNucor Head FabricatorNucor
Material Standard CodeASTM A706 Headed Bar Unique ID9FW-17-04

Test Details

DIME Sample ID: 2022-11-01-7
DIME Test ID: 2022-11-01-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2022-11-08

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 11/07/2022
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
120.4444838101905ok neckingspaine

General comments (publicly viewable) (Max 1000 characters): ok necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 11/8/2022