Summary for Test 2022-10-11-49-4

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 994100
DEA: 070Q8804
EFIS: 0721000106
MINOR: 07A5307
DIST-CO-RTE-PM07-LA-164-3.6
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 07/06/2022)

Sample Information

Sample Taken Date10/11/2022 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/19/2022
Sample typePer Request A brief description of the samplePG Asphalt Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byVulcan QC Last name of sampler or witnessed byVulcan QC
Title of sampler Telephone number of sampler
Laboratory sample identification0697-22 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan-Corona Drum Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2022-10-11-49
DIME Test ID: 2022-10-11-49-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2022-10-31

Test Results


Is viscosity reading in cP/Pa-s?: cP
Input Type: Calculated
Tester's full name: Majid Essa
Date of test: 10/21/2022
Time of test: 12:30 HH:MM
Test Temperature: 135 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 59 %
Viscosity reading #1 (A) : 0.296 cP
Viscosity reading #2 (B) : 0.297 cP
Viscosity reading #3 (C): 0.298 cP
Average viscosity : 0.297 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/31/2022