Summary for Test 2022-08-31-58-3

Test performed: AASHTO T85-13

Project Information

Project IdentifiersProject ID: 993603
DEA: 051N7004
EFIS: 0521000081
DIST-CO-RTE-PM05-SLO-166-16.0/21.0
Award Date04/22/2022
Closeout Date03/28/2023
Work DescriptionPARTIAL DEPTH RECYCLING AND OVERLAY WITH RHMA (GAP GRADED).
Location DescriptionSAN LUIS OBISPO COUNTY ABOUT 8 MILES EAST OF SANTA MARIA FROM 0.5 MILE WEST OF HUASNA RIVER BRIDGE TO 1.9 MILES WEST OF CUYAMA RIVER BRIDGE.
QA Service Level1 (Verified on 03/28/2022)

Sample Information

Sample Taken Date08/31/2022 Sample Unique Key58
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/19/2022
Sample typeDispute Resolution A brief description of the sampleAggregate
The quantity of what the sample constitutesL1SL16 From where was the sample collectedManufacturer
First name of sampler or witnessed byIsaac Last name of sampler or witnessed byGleffe
Title of samplerARET Telephone number of sampler18053191237
Laboratory sample identification22-JMFD-0155 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSPM-Templeton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0006
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSource
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number16 Aggregate Mix Number

Test Details

DIME Sample ID: 2022-08-31-58
DIME Test ID: 2022-08-31-58-3
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Test Release Date: 2022-10-24

Test Results


Basis for relative density testing: Bulk
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 10/21/2022
Mass of sample saturated surface dry aggregate: 3475.6 grams
Mass of sample in water: 2157.3 grams
Mass of sample after oven drying: 3409.2 grams
Specific Gravity: 2.586
Absorption: 1.9 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/24/2022