Summary for Test 2022-10-07-46-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 215220 DEA: 07210624 EFIS: 0719000068 |
---|---|
DIST-CO-RTE-PM | 07-LA,SBD-71-1.8/R4.7&R0.0/R0.2 |
Award Date | 02/05/2021 |
Closeout Date | Not set |
Work Description | PLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP. |
Location Description | IN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE. |
QA Service Level | 1 (Verified on 03/24/2021) |
Sample Information
Sample Taken Date | 10/07/2022 | Sample Unique Key | 46 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/07/2022 |
Sample type | Quality Assurance | A brief description of the sample | Native Material |
The quantity of what the sample constitutes | 342 Square Ft. | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Fernando | Last name of sampler or witnessed by | Carranza |
Title of sampler | Material Tester | Telephone number of sampler | |
Laboratory sample identification | 22-2676 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | N/A | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | CTM 231 Test Holes | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2022-10-07-46
DIME Test ID: 2022-10-07-46-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-10-21
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Fernando Carranza
Date of test: 10/07/2022
Gage No.: 80489
Test No.: 1
Nuclear By: Fernando Carranza
Non-Bias Plan No.: 3
Depth: 12
Material No.: Subgrade
Material Type: Native
Impact By: Fernando Carranza
Standard Count Density: 2309 g/cc
Count or Density 1: 313 g/cc
Count or Density 2: 304 g/cc
Count or Density 3: 299 g/cc
Standard Count Moisture: 816 g/cc
Moisture Count 1: 221 g/cc
Moisture Count 2: 205 g/cc
Moisture Count 3: 209 g/cc
Sum of Count or Density: 916 g/cc
Average of Count or Density: 305 g/cc
Sum of Moisture Count: 635 g/cc
Average of Moisture Count: 212 g/cc
Count Ratio Density: 0.13
Count Ratio Moisture: 0.26
Calculated Percent Relative Compaction: 97 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/21/2022 ✔