Summary for Test 2022-10-10-8-4
Test performed: ASTM A970-18Project Information
Project Identifiers | Project ID: 215188 DEA: 080F5434 EFIS: 0817000239 Permit Numbers: 0823NMC0369 |
---|---|
DIST-CO-RTE-PM | 08-RIV-I-15,SR-91-6.1-7.6 |
Award Date | 03/11/2020 |
Closeout Date | 06/05/2024 |
Work Description | I-15 ELC: 15/91 Express Lanes Connector Project (ELC) |
Location Description | Junction of I-15 and SR-91 in Corona, CA |
QA Service Level | 1 (Verified on 09/16/2020) |
Sample Information
Sample Taken Date | 10/10/2022 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/17/2022 |
Sample type | Quality Assurance | A brief description of the sample | #9 HRC 150 T-Head |
The quantity of what the sample constitutes | 165 Qty. #9 HRC 150 T-Heads | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Henry | Last name of sampler or witnessed by | Arredondo |
Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 5623329603 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | HRC Fountain Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 4115449 | Head Manufacturer Lot Number(s) | U/ A |
Rebar Size | #9 | Headed Bar Model Name | HRC 150 T Head |
Size of Head | Full Size - 9x | Head Connection Type | Friction Weld |
Head Shape | Circular | Rebar Manufacturer | CMC Steel Arizona |
Head Manufacturer | Nucor Utah | Head Fabricator | HRC Fountain Valley |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | 9FW-17-04 |
Test Details
DIME Sample ID: 2022-10-10-8
DIME Test ID: 2022-10-10-8-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2022-10-20
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/19/2022
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 3 | 1 | 100854 | 100854 | Head Broke Off | spaine |
General comments (publicly viewable) (Max 1000 characters): Head Broke Off
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 10/20/2022 ✔