Summary for Test 2022-10-10-8-4

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
Permit Numbers: 0823NMC0369
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Award Date03/11/2020
Closeout Date06/05/2024
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
QA Service Level1 (Verified on 09/16/2020)

Sample Information

Sample Taken Date10/10/2022 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/17/2022
Sample typeQuality Assurance A brief description of the sample#9 HRC 150 T-Head
The quantity of what the sample constitutes165 Qty. #9 HRC 150 T-Heads From where was the sample collectedFabricator
First name of sampler or witnessed byHenry Last name of sampler or witnessed byArredondo
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler5623329603
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Fountain Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4115449 Head Manufacturer Lot Number(s)U/ A
Rebar Size#9 Headed Bar Model NameHRC 150 T Head
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeCircular Rebar ManufacturerCMC Steel Arizona
Head ManufacturerNucor Utah Head FabricatorHRC Fountain Valley
Material Standard CodeASTM A706 Headed Bar Unique ID9FW-17-04

Test Details

DIME Sample ID: 2022-10-10-8
DIME Test ID: 2022-10-10-8-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2022-10-20

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/19/2022
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
131100854100854Head Broke Offspaine

General comments (publicly viewable) (Max 1000 characters): Head Broke Off
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 10/20/2022