Summary for Test 2022-07-19-81-7
Test performed: AASHTO T48-18Project Information
Project Identifiers | Project ID: 993612 DEA: 112N1184 EFIS: 1121000147 |
---|---|
DIST-CO-RTE-PM | 11-SD-78-60.3/66.4 |
Award Date | 04/18/2022 |
Closeout Date | 03/28/2023 |
Work Description | COLD PLANE, RHMA-G OVERLAY, SHOULDER BACKING AND STRIPING. |
Location Description | SAN DIEGO COUNTY NEAR JULIAN FROM WYNOLA ROAD TO 3.5 MILES WEST OF SAN FELIPE CREEK |
QA Service Level | 1 (Verified on 03/07/2022) |
Sample Information
Sample Taken Date | 07/19/2022 | Sample Unique Key | 81 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2022 |
Sample type | Acceptance | A brief description of the sample | PG Asphalt Binder |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Carrera |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | C962976 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-07-19-81
DIME Test ID: 2022-07-19-81-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2022-10-08
Test Results
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Calculated
Tester's full name: Majid Essa
Date of test: 08/24/2022
Observed Flash Point: 306 C
Ambient Barometric Pressure: 728 mmHg
Cleveland Open-Cup Flash Point in Celsius: 306 C
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/8/2022 ✔