Summary for Test 2016-08-24-15-9
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 08/24/2016 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/30/2016 |
Sample type | Recertification | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 16 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Russel | Last name of sampler or witnessed by | Lynch |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | C970415 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L9609716 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 082816 |
Hoop Manufacturer Lot Number(s) | NA | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 7 |
Diameter of Hoop | 29, 60 | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-08-24-15
DIME Test ID: 2016-08-24-15-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2016-10-04
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/08/2016
UTM: 400KIP
Temperature: 72 F
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | Cycle-1 Large | 100 | #7/22mm | Janda Resistance F4-300 | 0.6 | 58730 | 97883 | NECKING OK | Brian |
General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point FileTest was verified on 10/4/2016 ✔