Summary for Test 2022-10-01-3-3
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 214336 DEA: 07302404 EFIS: 0713000488 |
---|---|
DIST-CO-RTE-PM | 07-VEN-101-37/40 |
Award Date | 11/17/2020 |
Closeout Date | 09/24/2024 |
Work Description | PADRE JUAN REHAB |
Location Description | VEN 101 |
QA Service Level | 1 (Verified on 02/26/2021) |
Sample Information
Sample Taken Date | 10/01/2022 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/03/2022 |
Sample type | Department Acceptance | A brief description of the sample | LCB Aggregate |
The quantity of what the sample constitutes | 1 Bag of recycled base Aggregate | From where was the sample collected | Source |
First name of sampler or witnessed by | Avo | Last name of sampler or witnessed by | karajian |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Granite Construction | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Granite Yard - recycled Base |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Conveyor Belt | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | G3-22-LRCBRS-298R | Lot number | |
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-10-01-3
DIME Test ID: 2022-10-01-3-3
Testing Lab: CT D07 - Plant Services
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-10-10
Test Results
Number of tests: 2
Input Type: Measured
Tester's full name: Avo Karajian
Date of test: 10/03/2022
Temperature correction: 0
Temperature of solution: 75
Clay reading (test 1): 6
Sand reading (test 1): 3.5
Clay reading (test 2): 6
Sand reading (test 2): 3.6
Sand equivalent (test 1): 59
Sand equivalent (test 2): 60
Sand equivalent before temperature correction: 60
Sand equivalent after temperature correction: 60
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/10/2022 ✔