Summary for Test 2022-08-26-80-1
Test performed: ASTM C39-18Project Information
Project Identifiers | Project ID: 215639 DEA: 100S6804 EFIS: 1014000100 |
---|---|
DIST-CO-RTE-PM | 10-ALP-4,88,89-Var |
Award Date | 06/21/2021 |
Closeout Date | Not set |
Work Description | REPLACE CULVERTS, HEADWALLS AND REPLACE END TREATMENTS. |
Location Description | ALPINE COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 04/21/2021) |
Sample Information
Sample Taken Date | 08/26/2022 | Sample Unique Key | 80 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/26/2022 |
Sample type | Quality Control | A brief description of the sample | 4x8 concrete cylinders |
The quantity of what the sample constitutes | Day's Production | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Wilfredo | Last name of sampler or witnessed by | Bucaneg |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Rinker Materials | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | mix5 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 2 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Besser Hopper | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-08-26-80
DIME Test ID: 2022-08-26-80-1
Testing Lab: Rinker Materials
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2022-10-01
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jose Sanchez
Date of test: 08/27/2022
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 50895 lb
Maximum load on cylinder 2: 48205 lb
Maximum load on cylinder 3: 49480 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 3 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 3940 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/1/2022 ✔