Summary for Test 2022-09-14-60-1
Test performed: AASHTO T315-22Project Information
Project Identifiers | Project ID: 215367 DEA: 021J4904 EFIS: 0220000084 |
---|---|
DIST-CO-RTE-PM | 02-TEH-32-14.0/20.0 |
Award Date | 02/02/2021 |
Closeout Date | 04/11/2024 |
Work Description | PLACE HOT MIX ASPHALT (TYPE A). |
Location Description | TEHAMA COUNTY ABOUT 28 MILES EAST OF FOREST RANCH FROM 1.1 MILES EAST OF DEER CREEK BRIDGE NO. 08-0068 TO 0.4 MILE WEST OF SLATE CREEK BRIDGE NO. 08-0154 |
QA Service Level | 1 (Verified on 12/24/2020) |
Sample Information
Sample Taken Date | 09/14/2022 | Sample Unique Key | 60 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/22/2022 |
Sample type | Acceptance | A brief description of the sample | PG 58-34M |
The quantity of what the sample constitutes | 2 cans | From where was the sample collected | Source |
First name of sampler or witnessed by | R | Last name of sampler or witnessed by | S |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero | Transportation Laboratory (TL) Number | 876991 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-34 M |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-09-14-60
DIME Test ID: 2022-09-14-60-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-09-28
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eslam Mosallem
Date of test: 09/26/2022
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.261 kPa
Phase Angle (δ) (for the 10 cycles): 62.5 degree
Complex Modulus (G*) (for the 10 measurements): 2.177 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 2.45 kPa
General comments (publicly viewable) (Max 1000 characters): OG
Test was verified on 9/28/2022 ✔