Summary for Test 2022-09-14-52-2
Test performed: AASHTO T275-07r12Project Information
Project Identifiers | Project ID: 212775 DEA: 024F2204 EFIS: 0212000073 |
---|---|
DIST-CO-RTE-PM | 02-TRI-3-58.7/61.9 |
Award Date | 02/25/2021 |
Closeout Date | 05/06/2024 |
Work Description | REPLACE STRUCTURAL CONCRETE BRIDGE AND CULVERTS AND PLACE HMA. |
Location Description | TRINITY COUNTY NEAR TRINITY CENTER FROM 58.7 MILES NORTH OF PREACHER MEADOWS ROAD TO 60.7 MILES SOUTH OF EL DORADO WAY |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 09/14/2022 | Sample Unique Key | 52 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/14/2022 |
Sample type | Department Acceptance | A brief description of the sample | 16 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28 M) with 23.6% RAP and virgin PG 58-34 M from Valero (Benicia, CA) |
The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | D79157 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | J.F. Shea Construction – Fawndale Rock and Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 857910 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-09-14-52
DIME Test ID: 2022-09-14-52-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2022-09-30
Test Results
Number of tests: 3
What test procedure is performed?: Method A
Input Type: Measured
Tester's full name: Colt Sweeny and Darrell Valasek
Date of test: 09/14/2022
Mass of the dry specimen in air: 4692.7 g
Mass of the dry specimen plus paraffin coating in air: 4770.5 g
Mass of the dry specimen plus paraffin coating in water: 2740.4 g
Specific gravity of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Mass 2 of the dry specimen in air: 4692 g
Mass 2 of the dry specimen plus paraffin coating in air: 4764.6 g
Mass 2 of the dry specimen plus paraffin coating in water: 2739.6 g
Specific gravity 2 of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Mass 3 of the dry specimen in air: 4693.8 g
Mass 3 of the dry specimen plus paraffin coating in air: 4766 g
Mass 3 of the dry specimen plus paraffin coating in water: 2735.6 g
Specific gravity 3 of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Bulk Specific Gravity: 2.414
Bulk Specific Gravity 2: 2.413
Bulk Specific Gravity 3: 2.407
Average Bulk Specific Gravity: 2.411
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/30/2022 ✔