Summary for Test 2022-09-13-16-2
Test performed: CTM 227-December 2014Project Information
Project Identifiers | Project ID: 214451 DEA: 07303704 EFIS: 0714000035 |
---|---|
DIST-CO-RTE-PM | 07-LA-101-8.0/27.3 |
Award Date | 12/19/2019 |
Closeout Date | 05/07/2024 |
Work Description | REPLACE CONCRETE BARRIERS. |
Location Description | THE CITY AND COUNTY OF LOS ANGELES FROM PILGRIMAGE OVERCROSSING TO VALLEY CIRCLE BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 08/12/2020) |
Sample Information
Sample Taken Date | 09/13/2022 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/13/2022 |
Sample type | Department Acceptance | A brief description of the sample | 3/8" X #8 |
The quantity of what the sample constitutes | 100 CY | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Hopkins |
Title of sampler | Plant Inspector | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | National RM Canoga Park | Transportation Laboratory (TL) Number | C091322B |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0046 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | National RM Canoga Park | A detailed description of where the material sample was collected | Stockpile @ Yard |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | S58522 | Lot number | |
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-09-13-16
DIME Test ID: 2022-09-13-16-2
Testing Lab: CT D07 - Plant Services
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2022-09-15
Test Results
Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Kevin Hopkins
Date of test: 09/14/2022
Top sediment column reading (single primary size): 0.5 in
Cleanness value (single primary size): 86
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/15/2022 ✔