Summary for Test 2022-08-22-62-1
Test performed: AASHTO T59-22Project Information
Project Identifiers | Project ID: 993573 DEA: 061C5204 EFIS: 0621000173 |
---|---|
DIST-CO-RTE-PM | 06-KIN-198-7.4/R9.4,R14.8/T21.6 |
Award Date | 04/19/2022 |
Closeout Date | Not set |
Work Description | COLD PLANE AC PAVEMENT AND PLACE RHMA (GAP GRADED) AND HMA (TYPE A). |
Location Description | KINGS COUNTY IN AND NEAR LEMOORE FROM 1.5 MILES WEST OF ROUTE 41/198 SEPARATION TO 0.1 MILE WEST OF NINETEENTH AVENUE OVERCROSSING AND FROM 0.1 MILE EAST OF FOURTEENTH AVENUE UNDERCROSSING TO 0.6 MILE EAST OF ROUTE 43/198 SEPARATION |
QA Service Level | 1 (Verified on 02/22/2022) |
Sample Information
Sample Taken Date | 08/22/2022 | Sample Unique Key | 62 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/29/2022 |
Sample type | Department Acceptance | A brief description of the sample | ss1h |
The quantity of what the sample constitutes | 1 jar | From where was the sample collected | Other |
First name of sampler or witnessed by | No TL101 | Last name of sampler or witnessed by | No TL101 |
Title of sampler | No TL101 | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | No TL101 | Transportation Laboratory (TL) Number | No TL101 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphaltic Emulsion | Emulsion Grade | SS-1h |
---|---|---|---|
Lot Number | Not set | Sub Lot | Not set |
Dilution Percentage Rate | Not set |
Test Details
DIME Sample ID: 2022-08-22-62
DIME Test ID: 2022-08-22-62-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2022-09-02
Test Results
How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 09/01/2022
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 443.8 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 422.4 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 441.4 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 419.9 g
Beaker 1 Residue: 42.8 %
Beaker 2 Residue: 43.0 %
Percentage of residue: 43 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/2/2022 ✔