Summary for Test 2022-08-23-68-1

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 993573
DEA: 061C5204
EFIS: 0621000173
DIST-CO-RTE-PM06-KIN-198-7.4/R9.4,R14.8/T21.6
Award Date04/19/2022
Closeout DateNot set
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE RHMA (GAP GRADED) AND HMA (TYPE A).
Location DescriptionKINGS COUNTY IN AND NEAR LEMOORE FROM 1.5 MILES WEST OF ROUTE 41/198 SEPARATION TO 0.1 MILE WEST OF NINETEENTH AVENUE OVERCROSSING AND FROM 0.1 MILE EAST OF FOURTEENTH AVENUE UNDERCROSSING TO 0.6 MILE EAST OF ROUTE 43/198 SEPARATION
QA Service Level1 (Verified on 02/22/2022)

Sample Information

Sample Taken Date08/23/2022 Sample Unique Key68
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/26/2022
Sample typeAcceptance A brief description of the sample64-16
The quantity of what the sample constitutes1 CAN From where was the sample collectedSource
First name of sampler or witnessed byB Last name of sampler or witnessed byLatham
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Coalinga Transportation Laboratory (TL) Number039789
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number1
Sublot number12 Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2022-08-23-68
DIME Test ID: 2022-08-23-68-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-09-09

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 09/02/2022
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.160 kPa
Phase Angle (δ) (for the 10 cycles): 89.3 degree
Complex Modulus (G*) (for the 10 measurements): 1.334 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.33 kPa
General comments (publicly viewable) (Max 1000 characters): OG

Test was verified on 9/9/2022