Summary for Test 2022-07-07-26-1
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 215584 DEA: 074W7804 EFIS: 0719000277 |
---|---|
DIST-CO-RTE-PM | 07-LA-110-6.8/19.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | REPLACE JOINT SEALS, APPLY METHACRYLATE ON DECKS AND SPALL REPAIR. |
Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM 220TH STREET ON-RAMP TO 0.1 MILE SOUTH OF MARTIN LUTHER KING JR BOULEVARD |
QA Service Level | 1 (Verified on 08/17/2021) |
Sample Information
Sample Taken Date | 07/07/2022 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/12/2022 |
Sample type | Quality Control | A brief description of the sample | 2 pints 204,chp,,8020 |
The quantity of what the sample constitutes | 25000 gallons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Gilberto | Last name of sampler or witnessed by | Gonzalez |
Title of sampler | Quality Control Manager | Telephone number of sampler | 7076245467 |
Laboratory sample identification | 943117 | Linked DIME Sample ID | 943117 |
The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | 22-70-291390 |
---|---|---|---|
Batch number | 2270291390 | Mix number | 2270291390 |
Test Details
DIME Sample ID: 2022-07-07-26
DIME Test ID: 2022-07-07-26-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2022-08-26
Test Results
Input Type: Measured
Tester's full name: Rachael Chavez
Date of test: 08/23/2022
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 19.2
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.11
Volatile content (ASTM D 2369) 30% max: 3.42
Flash point (ASTM D 3828) more than 180 deg F: 180
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 652
Tack free time, 400 minutes max: 350
General comments (publicly viewable) (Max 1000 characters): PCC - SSD bond strength (CA Test 551) and Tack free time accepted based on supplier's results.
Test was verified on 8/26/2022 ✔