Summary for Test 2022-08-08-49-4

Test performed: ASTM D2628-91r16

Project Information

Project IdentifiersProject ID: 993183
DEA: 031H2704
EFIS: 0316000082
DIST-CO-RTE-PM03-YUB-70-R11.2/13.5
Award Date10/14/2021
Closeout DateNot set
Work DescriptionUPGRADE BRIDGE RAILS & CONSTRUCT CONCRETE MEDIAN BARRIER.
Location DescriptionYUBA COUNTY NEAR LINDA AND MARYSVILLE FROM 2.4 MILES SOUTH OF FEATHER RIVER BOULEVARD UNDERCROSSING TO THE YUBA RIVER BRIDGE AND OVERHEAD
QA Service Level1 (Verified on 08/16/2021)

Sample Information

Sample Taken Date08/08/2022 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/10/2022
Sample typeQuality Assurance A brief description of the sampleJoint Seal
The quantity of what the sample constitutes1 From where was the sample collectedJob Site
First name of sampler or witnessed byKaveh Last name of sampler or witnessed byAladini
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWatson Bowman Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM2 - Type B Elastomeric Joint Seal Mfg. Lot Number(s)I0HSA
Manufacturer(s)Watson Bowman Temperature72
Humidity50 Comments
Joint Seal Size1.75

Test Details

DIME Sample ID: 2022-08-08-49
DIME Test ID: 2022-08-08-49-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D2628-91r16: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements
Test Release Date: 2022-09-06

Test Results


Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 08/24/2022
High or low tempurature: Low
Temperature: 72 f
Humidity: 50 %
Temp Recovery (22 hrs at -20F) Size Before (Height of Contact Face ): 1.75 in
Temp Recovery (22 hrs at -20F) Size After (Recovered Contact Face ): 1.701 in
Percent Recovery: 97 %
General comments (publicly viewable) (Max 1000 characters): COLD TEMP

Test was verified on 9/6/2022