Summary for Test 2022-08-11-54-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993439
DEA: 022J4204
EFIS: 0221000076
DIST-CO-RTE-PM02-TRI-3-R26.3/29.8
Award Date02/07/2022
Closeout Date10/06/2022
Work DescriptionHMA OVERLAY AND REPLACE AC SURFACING.
Location DescriptionTRINITY COUNTY NEAR DOUGLAS CITY FROM BROWNS CREEK BRIDGE TO READING CREEK BRIDGE
QA Service Level1 (Verified on 12/13/2021)

Sample Information

Sample Taken Date08/11/2022 Sample Unique Key54
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/11/2022
Sample typeAcceptance A brief description of the sample12 boxes of Lime Treated 3/8-inch Type A HMA with 25% RAP and virgin PG 58-34 M from Valero – Benicia
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byJD Last name of sampler or witnessed byAtkinson
Title of sampler Telephone number of sampler
Laboratory sample identificationD79124 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis – Northstate Asphalt (Redding, CA) Transportation Laboratory (TL) Number858101
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/8 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2022-08-11-54
DIME Test ID: 2022-08-11-54-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-08-26

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Arthur Mills
Date of test: 08/12/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.67 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.96 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/26/2022