Summary for Test 2022-08-20-2-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 993626
DEA: 070W0804
EFIS: 0721000034
DIST-CO-RTE-PM07-LA-405-28.0/31.6
Award Date05/09/2022
Closeout Date07/03/2023
Work DescriptionINDIVIDUAL SLAB REPLACEMENTS.
Location DescriptionLOS ANGELES COUNTY IN CULVER CITY AND LOS ANGELES FROM VENICE BOULEVARD SEPARATION TO WILSHIRE BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date08/20/2022 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/20/2022
Sample typeAcceptance A brief description of the sampleISR-RSC Beams
The quantity of what the sample constitutes140 CY From where was the sample collectedJob Site
First name of sampler or witnessed byMichelangelo Last name of sampler or witnessed bySese
Title of samplerTET Telephone number of sampler310-345-6204
Laboratory sample identification22-2141 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSecurity Paving - Florence Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberG3-220
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNA
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-08-20-2
DIME Test ID: 2022-08-20-2-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2022-08-23

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Michelangelo Sese
Date of test: 08/23/2022
Identification number: Set #1
Width of specimen: 6.0625 inch
Width of specimen 2: 6.125 inch
Width of specimen 3: 6.0625 inch
Depth of specimen: 6.1875 inch
Depth of specimen 2: 6 inch
Depth of specimen 3: 6.125 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 6340 lb
Maximum load applied 2: 5850 lb
Maximum load applied 3: 5570 lb
Curing history and apparent moisture condition of the specimen: Yes
If specimen was capped, ground or if leather shims were used: NA
Defects in specimen, including numbers of beams discarded during test: None
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 520 psi
Modulus of rupture 2: 500 psi
Modulus of rupture 3: 460 psi
Modulus of rupture average: 490 psi
General comments (publicly viewable) (Max 1000 characters): SB Rte. 405 @ Santa Monica Blvd. Off-Ramp

Test was verified on 8/23/2022