Summary for Test 2022-08-17-44-3
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 993697 DEA: 022J4504 |
---|---|
DIST-CO-RTE-PM | 02-TEH-36-56.0/R60.5 |
Award Date | 06/09/2022 |
Closeout Date | 10/06/2022 |
Work Description | PLACE HMA (TYPE A) AND REPLACE AC SURFACING. |
Location Description | TEHAMA COUNTY ABOUT 13 MILES EAST OF RED BLUFF FROM 0.7 MILE EAST OF MANTON ROAD TO 2.4 MILES EAST OF PAYNES CREEK BRIDGE |
QA Service Level | 1 (Verified on 04/05/2022) |
Sample Information
Sample Taken Date | 08/17/2022 | Sample Unique Key | 44 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/17/2022 |
Sample type | Department Acceptance | A brief description of the sample | 1 bag of Fine RAP (3/8-inch) |
The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | JD | Last name of sampler or witnessed by | Atkinson |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D79131B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Knife River Construction – Orland Plant (Orland, CA) | Transportation Laboratory (TL) Number | 857907 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | KRC Orland |
---|---|---|---|
Aggregate Size | 3/8-inch | Aggregate Source | |
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2022-08-17-44
DIME Test ID: 2022-08-17-44-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-08-22
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Karen Rios Dorado and K. Yang
Date of test: 08/18/2022
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.8 grams
Mass of oven-dry sample in air for Sample 1: 1564.5 grams
Mass of container filled with the sample and water for Sample 1: 8300.0 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.606
Theoretical maximum density at 25°C (77°F): 162.2 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/22/2022 ✔