Summary for Test 2022-06-21-8-1
Test performed: CONCLP 2-16Project Information
Project Identifiers | Project ID: 993445 DEA: 101M3504 EFIS: 1020000181 |
---|---|
DIST-CO-RTE-PM | 10-SJ-132-L0.7/5.8 |
Award Date | 03/03/2022 |
Closeout Date | 05/10/2023 |
Work Description | REPLACE APPROACH SLAB AND PLACE POLYESTER CONCRETE OVERLAY. |
Location Description | SAN JOAQUIN COUNTY NEAR VERNALIS AT VARIOUS LOCATIONS FROM ROUTE 132 EAST/580 SEPARATION TO ROUTE 132/33 SEPARATION AND OVERHEAD |
QA Service Level | 1 (Verified on 12/13/2021) |
Sample Information
Sample Taken Date | 06/21/2022 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/24/2022 |
Sample type | Per Request | A brief description of the sample | Rapid Setting Mortar |
The quantity of what the sample constitutes | 12 Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Thao | Last name of sampler or witnessed by | Vu |
Title of sampler | Telephone number of sampler | 5623320278 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Sika - Santa Fe Springs | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Rapid Set | Manufacturer | Sika |
---|---|---|---|
Mix no. | 01 | Materials Received | 06/21/2022 |
Lot no. | 3006384921 | Batch no. | 06212201 |
Test Details
DIME Sample ID: 2022-06-21-8
DIME Test ID: 2022-06-21-8-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 2-16: Rapid Set Patching Materials
Test Release Date: 2022-08-19
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 08/03/2022
Compressive Strength @ 3 hrs (CTM 551): 4660
Compressive Strength @ 24 hrs (CTM 551): 5800
Flexure Strength @ 24 hrs (CTM 551): 0
Bond Strength @ 24 hrs - SSD (CTM 551): 0
Bond Strength @ 24 hrs - Dry (CTM 551): 0
Water Absorption (CTM 551): 0
Abrasion @ 24 hrs (CTM 550): 23
Drying Shrinkage @ 4 days (CTM 596): 0
Soluble Chlorides (CTM 422): 0.0005
Water Soluble-Sulfates (CTM 417): 0.0534
Material Weight: 50
Water Weight: 5.7
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/19/2022 ✔