Summary for Test 2022-05-20-55-3

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 993594
DEA: 120S9104
EFIS: 1221000060
DIST-CO-RTE-PM12-ORA-57-11.0/22.2
Award Date04/07/2022
Closeout Date09/07/2023
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE RHMA-G.
Location DescriptionORANGE COUNTY AT VARIOUS LOCATIONS FROM 0.2 MILE SOUTH OF CHAPMAN AVENUE UNDERCROSSING TO 0.3 MILE SOUTH OF LOS ANGELES COUNTY LINE
QA Service Level1 (Verified on 03/21/2022)

Sample Information

Sample Taken Date05/20/2022 Sample Unique Key55
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/01/2022
Sample typeVerification A brief description of the sampleJMF 1/2" RWHMA-G-SP 0.25% Evo
The quantity of what the sample constitutes22 Boxes,4 bags,4qt can From where was the sample collectedSupplier
First name of sampler or witnessed byR.J.NOBLE QC Last name of sampler or witnessed byR.J.NOBLE QC
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameR.J.NOBLE Orange Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierLunday Thagard Company-World Oil - South Gate CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2022-05-20-55
DIME Test ID: 2022-05-20-55-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2022-08-15

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 08/10/2022
Ductility of test #1 (D1): 75 cm
Ductility of sample: 75 cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/15/2022