Summary for Test 2022-07-26-39-3

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 215789
DEA: 10462104
EFIS: 1013000266
DIST-CO-RTE-PM10-TUO-108-R18.9/38.8
Award Date08/02/2021
Closeout Date06/26/2023
Work DescriptionCOLD PLANE, HMA, DRAINAGE REPLACEMENT, AND MODIFY TRAFFIC STATIONS.
Location DescriptionTUOLUMNE COUNTY IN AND NEAR LONG BARN FROM 0.1 MILE WEST OF LONG BARN ROAD TO 2.3 MILES EAST OF COW CREEK ROAD
QA Service Level1 (Verified on 06/04/2021)

Sample Information

Sample Taken Date07/26/2022 Sample Unique Key39
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/02/2022
Sample typeAcceptance A brief description of the sample3/4 " HMA-A SP R22 PG 58-34M
The quantity of what the sample constitutes1 can From where was the sample collectedFabricator
First name of sampler or witnessed byJ Last name of sampler or witnessed byKort
Title of samplerPlant Inspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGeorge Reed - Table Mountain Plant Transportation Laboratory (TL) Number710267
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2022-07-26-39
DIME Test ID: 2022-07-26-39-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-08-15

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 08/10/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 27.421 kPa
Phase Angle (δ) (for the 10 cycles): 37.5 degree
Complex Modulus (G*) (for the 10 measurements): 2742.099 kPa
Test Temperature (Specimen 1): 16.0 C
(G*) x sin(δ)=: 1669 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 8/15/2022