Summary for Test 2022-07-06-52-3

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 993623
DEA: 022J3704
EFIS: 0221000071
DIST-CO-RTE-PM02-SHA-299-50.5/56.5,93.5/99.3
Award Date04/29/2022
Closeout Date10/06/2022
Work DescriptionASPHALT RUBBER BINDER SEAL COAT, COLD PLANE AC PAVEMENT AND HMA.
Location DescriptionSHASTA COUNTY NEAR MONTGOMERY CREEK FROM 0.2 MILE WEST OF OAK POINT DRIVE TO OLD BERTAGNA PLACE AND FROM 0.1 MILE EAST OF SIERRA CENTER DRIVE TO LASSEN COUNTY LINE
QA Service Level1 (Verified on 03/18/2022)

Sample Information

Sample Taken Date07/06/2022 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/29/2022
Sample typeDepartment Acceptance A brief description of the sampleBINDER // PSE // JMF RENEWAL
The quantity of what the sample constitutes1 of 2 cans From where was the sample collectedSource
First name of sampler or witnessed bySEE Last name of sampler or witnessed byTL101
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVALERO Transportation Laboratory (TL) NumberC867308
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2022-07-06-52
DIME Test ID: 2022-07-06-52-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-08-09

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 08/08/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 49.343 kPa
Phase Angle (δ) (for the 10 cycles): 44.6 degree
Complex Modulus (G*) (for the 10 measurements): 4934.437 kPa
Test Temperature (Specimen 1): 22.0 C
(G*) x sin(δ)=: 3465 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 8/9/2022