Summary for Test 2022-07-25-55-5
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/25/2022 | Sample Unique Key | 55 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/25/2022 |
Sample type | Verification | A brief description of the sample | Tank 60002 |
The quantity of what the sample constitutes | 1 of 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Edgard | Last name of sampler or witnessed by | Hitti |
Title of sampler | Not set | Telephone number of sampler | Not set |
Laboratory sample identification | 1659352446 | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Bakersfield, CA | Transportation Laboratory (TL) Number | Not set |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | Not set | Lot number | Not set |
Sublot number | Not set | Tank number | Not set |
Time of sample | Not set | HMA Supplier | Not set |
Certified Asphalt Supplier | Centennial Asphalt | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-07-25-55
DIME Test ID: 2022-07-25-55-5
Testing Lab: Granite Construction Company - Bakersfield
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-08-08
Test Results
Phase: PAV residue
Input Type: Calculated
Tester's full name: Garco
Date of test: 08/08/2022
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): no data
(G*) x sin(δ)=: 4299 kPa
General comments (publicly viewable) (Max 1000 characters): Submitted from ASCP bulk upload.
Test was verified on 8/8/2022 ✔