Summary for Test 2022-08-02-14-2
Test performed: CTM 227-December 2014Project Information
Project Identifiers | Project ID: 993316 DEA: 07325304 EFIS: 0716000083 |
---|---|
DIST-CO-RTE-PM | 07-LA-118-R1.5/R10.2 |
Award Date | 12/27/2021 |
Closeout Date | Not set |
Work Description | CONSTRUCT STORM WATER TREATMENT DEVICES AND IMPORTED BORROW. |
Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM 0.3 MILE WEST OF ROUTE 118/27 SEPARATION TO 0.2 MILE EAST OF SEPULVEDA BOULEVARD UNDERCROSSING |
QA Service Level | 1 (Verified on 11/30/2021) |
Sample Information
Sample Taken Date | 08/02/2022 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/03/2022 |
Sample type | Department Acceptance | A brief description of the sample | PCC Aggregate |
The quantity of what the sample constitutes | 3 Bags of Aggs | From where was the sample collected | Source |
First name of sampler or witnessed by | Avo | Last name of sampler or witnessed by | Karajian |
Title of sampler | TET | Telephone number of sampler | 12137986076 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | National Ready Mix - Canoga | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0046 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Granite - Big Rock Creek | The fabricator/manufacturer designation for the sample | |
The plant number | A detailed description of where the material sample was collected | Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | S73C445T13 | Lot number | |
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-08-02-14
DIME Test ID: 2022-08-02-14-2
Testing Lab: CT D07 - Plant Services
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2022-08-17
Test Results
Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Avo Karajian
Date of test: 08/03/2022
Top sediment column reading (single primary size): 0.5 in
Cleanness value (single primary size): 86
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/17/2022 ✔