Summary for Test 2022-07-28-8-2

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 993131
DEA: 010A1104
EFIS: 0112000211
DIST-CO-RTE-PM01-HUM-101-27.7
Award Date09/21/2021
Closeout DateNot set
Work DescriptionBRIDGE SEISMIC RETROFIT AND ROCK SLOPE PROTECTION.
Location DescriptionHUMBOLDT COUNTY NEAR MYERS FLAT AT SOUTH FORK EEL RIVER BRIDGE
QA Service Level1 (Verified on 07/22/2021)

Sample Information

Sample Taken Date07/28/2022 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/01/2022
Sample typeQuality Assurance A brief description of the sample1" x 4 1/2" A325 HDG Bolts with nuts and washers
The quantity of what the sample constitutes263 each From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of samplerAssociate Steel Inspector Telephone number of sampler510-376-7155 cell
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameC&K Johnson Industries Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB9-107-22 Structure unique identifier04-0123
Structure nameSouth Fork Eel River

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)466735AR
Heat Number(s)Bolt 1000213628 Nut 8000010208 washer A64353 Nut Mfg. Lot Number(s)459462A
Washer Mfg. Lot Number(s)E0179 Bolt SpecificationA325
Bolt Length(s)4 1/2" Nut SpecificationA563 DH
Washer SpecificationF436 FinishHDG
Diameter/Size1" Bolt Mfg. Lot Number466735A
Rocap Test Requirement(s)yes Lubricant Requirements(s)yes

Test Details

DIME Sample ID: 2022-07-28-8
DIME Test ID: 2022-07-28-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2022-08-05

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 08/03/2022
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A466735A1.000089194396.7610.00A325 Wedge Tensilespaine

General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 8/5/2022