Summary for Test 2022-07-25-1-6
Test performed: ASTM A970-18Project Information
Project Identifiers | Project ID: 215255 DEA: 040A7714 EFIS: 0420000287 |
---|---|
DIST-CO-RTE-PM | 04-ALA-80-6.4-6.6 |
Award Date | 05/03/2021 |
Closeout Date | 12/01/2023 |
Work Description | CONSTRUCT PEDESTRIAN OVERCROSSING BRIDGE AND RETAINING WALLS. GILMAN INTERCHANGE IMPROVEMENTS |
Location Description | ALAMEDA COUNTY IN BERKELEY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.1 MILE SOUTH OF GILMAN STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 12/07/2020) |
Sample Information
Sample Taken Date | 07/25/2022 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/27/2022 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A706 Grade 60 HRC 120 T Heads |
The quantity of what the sample constitutes | 480 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
Title of sampler | Steel Associate Inspector | Telephone number of sampler | 7073428602 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | HRC Fountain Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-082-22 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 4119819 | Head Manufacturer Lot Number(s) | 100021624144 |
Rebar Size | #5 | Headed Bar Model Name | HRC 120 T Heads |
Size of Head | Full Size - 9x | Head Connection Type | Friction Weld |
Head Shape | Square | Rebar Manufacturer | CMC Steel Arizona |
Head Manufacturer | Nucor Utah | Head Fabricator | HRC Fountain Valley |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2022-07-25-1
DIME Test ID: 2022-07-25-1-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2022-08-01
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 07/29/2022
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 4 | 0.31 | 29120 | 93934 | Ok Necking | spaine |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 8/1/2022 ✔