Summary for Test 2022-07-11-59-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993344
DEA: 022J3804
EFIS: 0221000072
DIST-CO-RTE-PM02-SIS-3-R48.0/51.0
Award Date12/20/2021
Closeout Date07/27/2023
Work DescriptionHMA OVERLAY AND REPLACE AC SURFACING.
Location DescriptionSISKIYOU COUNTY IN AND NEAR YREKA FROM 0.1 MILE SOUTH OF JUNIPER DRIVE TO 0.3 MILE NORTH OF CALAMITY LANE
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date07/11/2022 Sample Unique Key59
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/11/2022
Sample typeAcceptance A brief description of the sampleCombined RAP
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byClint Last name of sampler or witnessed byRogers
Title of samplerPEI Tech Telephone number of sampler
Laboratory sample identificationD79084B Linked DIME Sample ID2022-07-11-58, 2022-07-11-60
The fabricator/manufacturer/facility nameTullis - Northstate Asphalt - Redding, CA Transportation Laboratory (TL) Number891178
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceTullis, Northstate Asphalt, Redding, CA
Aggregate Size1/2-inch Aggregate Source
RAP StockpileContinuous Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2022-07-11-59
DIME Test ID: 2022-07-11-59-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-07-28

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Khue Yang and Arthur Mills
Date of test: 07/14/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 4.67 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/28/2022