Summary for Test 2022-07-11-59-1
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 993344 DEA: 022J3804 EFIS: 0221000072 |
---|---|
DIST-CO-RTE-PM | 02-SIS-3-R48.0/51.0 |
Award Date | 12/20/2021 |
Closeout Date | 07/27/2023 |
Work Description | HMA OVERLAY AND REPLACE AC SURFACING. |
Location Description | SISKIYOU COUNTY IN AND NEAR YREKA FROM 0.1 MILE SOUTH OF JUNIPER DRIVE TO 0.3 MILE NORTH OF CALAMITY LANE |
QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
Sample Taken Date | 07/11/2022 | Sample Unique Key | 59 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/11/2022 |
Sample type | Acceptance | A brief description of the sample | Combined RAP |
The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Clint | Last name of sampler or witnessed by | Rogers |
Title of sampler | PEI Tech | Telephone number of sampler | |
Laboratory sample identification | D79084B | Linked DIME Sample ID | 2022-07-11-58, 2022-07-11-60 |
The fabricator/manufacturer/facility name | Tullis - Northstate Asphalt - Redding, CA | Transportation Laboratory (TL) Number | 891178 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Tullis, Northstate Asphalt, Redding, CA |
---|---|---|---|
Aggregate Size | 1/2-inch | Aggregate Source | |
RAP Stockpile | Continuous | Stockpile Size (tons) | |
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2022-07-11-59
DIME Test ID: 2022-07-11-59-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-07-28
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Arthur Mills
Date of test: 07/14/2022
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.7 grams
Mass of oven-dry sample in air for Sample 1: 2575.3 grams
Mass of container filled with the sample and water for Sample 1: 8907.4 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.566
Theoretical maximum density at 25°C (77°F): 159.7 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/28/2022 ✔