Summary for Test 2022-07-18-23-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993344 DEA: 022J3804 EFIS: 0221000072 |
---|---|
DIST-CO-RTE-PM | 02-SIS-3-R48.0/51.0 |
Award Date | 12/20/2021 |
Closeout Date | 07/27/2023 |
Work Description | HMA OVERLAY AND REPLACE AC SURFACING. |
Location Description | SISKIYOU COUNTY IN AND NEAR YREKA FROM 0.1 MILE SOUTH OF JUNIPER DRIVE TO 0.3 MILE NORTH OF CALAMITY LANE |
QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
Sample Taken Date | 07/18/2022 | Sample Unique Key | 23 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/19/2022 |
Sample type | Acceptance | A brief description of the sample | 1 box of Lime Treated 3/8-inch Type A HMA (eq. PG 64-28 M) with 24.0% RAP and virgin PG 58-34 M from Valero – Benecia |
The quantity of what the sample constitutes | 750 tons | From where was the sample collected | Job Site |
First name of sampler or witnessed by | M. | Last name of sampler or witnessed by | Birkland |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | D79101 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Tullis – Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 853091 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/8 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-07-18-23
DIME Test ID: 2022-07-18-23-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-08-01
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Arthur Mills
Date of test: 07/25/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.67 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.79 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/1/2022 ✔