Summary for Test 2016-07-21-3-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 209135 DEA: 04235844 EFIS: 0400000684 COOP: 042493 |
---|---|
DIST-CO-RTE-PM | 04-SM-101-16.3/17.06 |
Award Date | 06/25/2014 |
Closeout Date | 12/17/2019 |
Work Description | RECONSTRUCT OVERCROSSING, RETAINING WALLS, GROUND IMPROVEMENT, |
Location Description | BURLINGAME |
QA Service Level | 1 (Verified on 10/03/2013) |
Sample Information
Sample Taken Date | 07/21/2016 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2016 |
Sample type | Quality Assurance | A brief description of the sample | BarGrip XL Coupler |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Macasio | Last name of sampler or witnessed by | Casas |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Barsplice, Nucor | Transportation Laboratory (TL) Number | C581392 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | N/A | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | Barsplice | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | #6 | Coupler Model | BarGrip XL |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | 2M60886 | Rebar Heat Number(s) | PL15108051, PL15208070 |
Rebar Size 2 | NA | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2016-07-21-3
DIME Test ID: 2016-07-21-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-07-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/22/2016
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 3 | N/A | #6/19mm | 0.44 | 0 | 40354 | 91714 | OK Necking | Fred |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 7/25/2016 ✔