Summary for Test 2022-06-15-52-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award DateNot set
Closeout DateNot set
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date06/15/2022 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/21/2022
Sample typeAcceptance A brief description of the sample1/2 RHMA-G
The quantity of what the sample constitutes1050 tons From where was the sample collectedManufacturer
First name of sampler or witnessed byVictor Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler2137924794
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Sun Valley Transportation Laboratory (TL) NumberC0615A1
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035
The fabricator's/manufacturer's product name for the sample326120 SVA3 VLO The fabricator/manufacturer designation for the sample1/2 RHMA-G
The plant numberSun Valley A detailed description of where the material sample was collectedBatch Plant Hot Bins
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-06-15-52
DIME Test ID: 2022-06-15-52-1
Testing Lab: CT D07 - Plant Services
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2022-07-15

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: D.Padilla
Date of test: 07/05/2022
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 96 %
Cumulative percent passing the 3/8 in. sieve: 85 %
Cumulative percent passing the #4 sieve: 35 %
Cumulative percent passing the #8 sieve: 22 %
Cumulative percent passing the #16 sieve: 14 %
Cumulative percent passing the #30 sieve: 9 %
Cumulative percent passing the #50 sieve: 5 %
Cumulative percent passing the #100 sieve: 3 %
Cumulative percent passing the #200 sieve: 1.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/15/2022