Summary for Test 2022-04-13-85-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 993345
DEA: 022J4004
EFIS: 0221000074
DIST-CO-RTE-PM02-LAS-395-56.5/R61.1
Award Date02/02/2022
Closeout Date11/23/2022
Work DescriptionCOLD PLANE ASPHALT CONCRETE PAVEMENT AND PLACE HMA.
Location DescriptionLASSEN COUNTY NEAR JANESVILLE FROM 0.1 MILE NORTH OF SUNNYSIDE ROAD TO 0.1 MILE NORTH OF ROUTE 36
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date04/13/2022 Sample Unique Key85
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/14/2022
Sample typeVerification A brief description of the sample1/2-inch Untreated Sized Virgin Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byTerry Last name of sampler or witnessed bySchmitt
Title of sampler Telephone number of sampler
Laboratory sample identificationD79020A Linked DIME Sample ID
The fabricator/manufacturer/facility nameHat Creek Construction and Materials - Ward Lake Plant (Litchfield, CA) Transportation Laboratory (TL) Number896946
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-18-0008::Ward Lake Pit
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSized Untreated Virgin Stockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberJMF 22-04-S01 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-04-13-85
DIME Test ID: 2022-04-13-85-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2022-07-12

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Karen Rios Dorado
Date of test: 04/18/2022
Cumulative Mass RetainedCumulative Percent Passing
5536 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
642.0 grams88.4 %
3975.0 grams28.2 %
5388 grams2.7 %
5407.0 grams2.3 %
19.6 grams2 %
29.5 grams1.8 %
36.2 grams1.7 %
43.2 grams1.5 %
53.1 grams1.4 %
65.8 grams1.13 %
grams
General comments (publicly viewable) (Max 1000 characters): Sample was fine on the 1/2 and 3/8-inch sieves.

Test was verified on 7/12/2022