Summary for Test 2022-06-02-19-6

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award DateNot set
Closeout DateNot set
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date06/02/2022 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/09/2022
Sample typeVerification A brief description of the sampleJMF 1/2" RHMA-G-SP 0.5% LAS
The quantity of what the sample constitutes6 Bags Of Agg., From where was the sample collectedManufacturer
First name of sampler or witnessed byChris Last name of sampler or witnessed byHurtado
Title of sampler Telephone number of sampler
Laboratory sample identification0347G-22 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials-Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number326120 SVA3 LTR A detailed description of where the material sample was collectedBelt Cut at Vulcan Materials-Sun Valley 3
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-06-02-19
DIME Test ID: 2022-06-02-19-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2022-07-28

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 06/15/2022
Bulk dry specific gravity: 2.641
Average uncompacted voids: 45.7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/28/2022