Summary for Test 2021-12-22-24-3

Test performed: CTM TEMP1-16

Project Information

Project IdentifiersProject ID: 215256
DEA: 100S7504
EFIS: 1014000099
DIST-CO-RTE-PM10-ALP,AMA,TUO-4,16,49,88,108,207-var
Award Date12/30/2020
Closeout Date12/05/2022
Work DescriptionREMOVE AND REPLACE DRAINAGE SYSTEMS.
Location DescriptionALPINE, AMADOR AND TUOLUMNE COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 11/02/2020)

Sample Information

Sample Taken Date12/22/2021 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/22/2022
Sample typeQuality Control A brief description of the sample4x8 concrete cylinders
The quantity of what the sample constitutesdays production From where was the sample collectedManufacturer
First name of sampler or witnessed by Jose Last name of sampler or witnessed bySanchez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameForterra Pipe and Precast, Florin Rd Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numbermix 5
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected2
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBesser Hopper Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-12-22-24
DIME Test ID: 2021-12-22-24-3
Testing Lab: Rinker Materials
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Test Release Date: 2022-07-06

Test Results


Input Type: Calculated
Tester's full name: Wally Bucaneg
Date of test: 12/23/2021
Precast Maximum Curing Temperature: 95.1 °F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/6/2022